Caracterización bacteriana de superficies inertes en unidades móviles de atención pre hospitalaria posterior a la desinfección de la ciudad de Cuenca 2023

dc.contributor.advisorArteaga Sarmiento, Sandra Denisse
dc.contributor.authorBenavides Rodríguez, William Rolando
dc.contributor.authorMorocho Malla, José Andrés
dc.contributor.cedula0107316689es_ES
dc.contributor.cedula0106446164es_ES
dc.coverageCuenca - Ecuadores_ES
dc.date.accessioned2023-10-11T18:34:38Z
dc.date.available2023-10-11T18:34:38Z
dc.date.issued2023
dc.descriptionINTRODUCCIÓN: LAS UNIDADES DE AMBULANCIA DESEMPEÑAN UN PAPEL CRUCIAL AL PROPORCIONAR atención prehospitalaria y transportar pacientes con afecciones graves. Sin embargo, puede ser fuente de contaminación cruzada principalmente bacterias, las cuales pueden comprometer la salud del paciente y poner en riesgo al personal médico, el cual se agrava más si no se establecen protocolos de desinfección adecuados. Objetivo: Caracterizar las bacterias presentes en las superficies inertes posterior a procesos de desinfección, con la finalidad de corroborar si el proceso de desinfección es adecuado. Metodología: El enfoque de investigación de tipo cualitativo, no experimental, con corte transversal, analítico y de campo. El universo de estudio formado por superficies inertes de las unidades móviles de atención prehospitalaria, una vez analizadas las bacterias sospechosas se identificaron mediante técnica Vitek 2, adicionalmente se realizó pruebas de susceptibilidad a los antibióticos. Resultados: Resultó el crecimiento en 15 sitios de los 60 analizados. Sin embargo, las bacterias sospechosas se analizaron y se identificaron: Staphylococcus hominis, Pseudomonas aeruginosa y Bacillus spp. Aquellas cepas que se consideran potencialmente patógenas en áreas de alta manipulación. Además, las pruebas de susceptibilidad a los antibióticos presentan tanto sensibilidad como resistencia frente a antibióticos específicos. Conclusión: Se concluye que la contaminación en las unidades es un tema grave, debido a su importancia durante el traslado en situaciones críticas, sin embargo, la misma puede provenir de diversas fuentes poniendo en riesgo la salud del personal y pacientes, por ello, es esencial mantener una atención rigurosa en los protocolos de limpieza y desinfección óptima.es_ES
dc.description.abstractIntroduction: Ambulance units play a crucial role in providing prehospital care and transporting patients with serious conditions. However, they can be a source of cross-contamination, primarily bacteria, which can compromise patient health and put medical personnel at risk. This risk is further heightened if adequate disinfection protocols are not established. Objective: To characterize the bacteria present on inert surfaces after disinfection processes, in order to corroborate whether the disinfection process is adequate. Methodology: The research approach was qualitative, non-experimental, cross-sectional, analytical, and field-based. The study universe consisted of inert surfaces of the mobile pre-hospital care units. Once the suspected bacteria were analyzed, they were identified using the Vitek 2 technique, and antibiotic susceptibility tests were also performed. Results: Growth was found in 15 of the 60 sites analyzed. However, suspected bacteria were analyzed and identified: Staphylococcus hominis, Pseudomonas aeruginosa, and Bacillus spp. These strains are considered potentially pathogenic in areas of high handling. Additionally, antibiotic susceptibility tests show both sensitivity and resistance to specific antibiotics. Conclusion: It is concluded that contamination in the units is a serious issue due to its importance during transfers in critical situations. However, it can originate from various sources, putting the health of staff and patients at risk. Therefore, it is essential to maintain rigorous attention to the protocols of cleaning and optimal disinfection.es_ES
dc.description.uriTrabajo de investigaciónes_ES
dc.formatapplication/pdfes_ES
dc.format.extent18 páginases_ES
dc.identifier.journalAnatomía Digitales_ES
dc.identifier.other6BT2023-BF-83
dc.identifier.urihttps://dspace.ucacue.edu.ec/handle/ucacue/15881
dc.language.isospaes_ES
dc.publisherUniversidad Católica de Cuenca.es_ES
dc.rightsinfo:eu-repo/semantics/openAccesses_ES
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/deed.eses_ES
dc.sourceUniversidad Católica de Cuencaes_ES
dc.sourceRepositorio Institucional - UCACUEes_ES
dc.subjectTRANSMISIÓNes_ES
dc.subjectBACTERIASes_ES
dc.subjectRESISTENCIAes_ES
dc.subjectPACIENTESes_ES
dc.titleCaracterización bacteriana de superficies inertes en unidades móviles de atención pre hospitalaria posterior a la desinfección de la ciudad de Cuenca 2023es_ES
dc.typeinfo:eu-repo/semantics/articlees_ES
thesis.degree.disciplineSalud y Bienestares_ES
thesis.degree.grantorUniversidad Católica de Cuenca. Bioquímica y farmaciaes_ES
thesis.degree.levelTítulo Profesionales_ES
thesis.degree.nameBioquímico Farmacéuticoes_ES
thesis.degree.programPresenciales_ES

Archivos

Bloque de licencias

Mostrando 1 - 1 de 1
No hay miniatura disponible
Nombre:
license.txt
Tamaño:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descripción:
logo ucacue
Universidad Católica de Cuenca

Teléfonos:

593 (07) 2-830-7512-830-8772-824-365

Email:

info@ucacue.edu.ecCentro de documentación
logo rraae
logo la referencia