dc.descriptionOBJETIVO: El presente estudio tuvo como objetivo comparar la capacidad disolutiva de dos solventes orgánicos frente a los selladores endodónticos más utilizados. \nMATERIALES Y MÉTODOS: La investigación se llevó a cabo en el laboratorio de Microbiología y Bromatología de Alimentos de la Universidad Católica de Cuenca. Se utilizaron moldes de acero inoxidable (n=204) que fueron llenados hasta el tope con los cementos selladores Sealapex, Tubliseal y MTA-Fillapex. Las muestras fraguaron durante al menos siete días en una incubadora. Posteriormente, se analizó la solubilidad de cada cemento con el uso de aceite de naranja y eucaliptol. Cada muestra de cemento fue sumergida por el lapso de diez minutos en cada uno de los solventes. Los resultados se evidenciaron a través del peso de las muestras antes y después de cada inmersión. También se puso a prueba la capacidad disolutiva de los solventes en un ambiente estático y en un ambiente ultrasónico. \nRESULTADOS: Los resultados fueron obtenidos con la prueba Shapiro-Wilks, y se demostró que el eucaliptol tuvo mayor acción disolutiva sobre MTA-Fillapex, mientras que el aceite de naranja tuvo mejor efecto sobre Sealapex. Finalmente no hubo diferencia estadísticamente significativa entre aceite de naranja y eucaliptol sobre Tubliseal. Así mismo, la activación ultrasónica del solvente tuvo mejores resultados que un ambiente estático.es_ES
dc.description.resumenAIM: The purpose of this study was to compare the dissolving capacity of two organic solvents with the most used endodontic sealers. \nMATERIALS AND METHODS: The study took place at the Microbiology and Food Bromatology Laboratory, where prefabricated stainless steel molds (n=204) were filled to the top with three endodontic sealers: Sealapex, Tubliseal, and MTA-Fillapex. The samples were left to set inside an incubator during at least seven days at 37°C. The solubility of each sealer was determined by analizing the weights of the sealer samples before and after being submerged in each solvent during 10 minutes in both an ultrasonic and static activation. \nRESULTS: The results were analyzed by the Shapiro-Wilks test, which showed that eucalyptus oil had a higher dissolving capacity than orange oil on MTA-Fillapex, whereas orange oil had higher dissolving capacity on Sealapex and finally there wasn’t any statistically significant difference on the solubility of Tubliseal on either solvent.es_ES
dc.formatapplication/pdfes_ES
dc.format.extent87es_ES
dc.identifier.urihttps://dspace.ucacue.edu.ec/handle/ucacue/4759
dc.language.isospaes_ES
dc.rightsAtribución 4.0 Internacional
dc.rightsinfo:eu-repo/semantics/openAccesses_ES
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/deed.es
dc.sourceUniversidad Católica de Cuencaes_ES
dc.sourceRepositorio Institucional - UCACUEes_ES
dc.subjectSolubilidades_ES
dc.subjectCementoes_ES
dc.subjectEucaliptoes_ES
dc.subjectAceitees_ES
dc.titleCapacidad disolutiva del Eucaliptol y Aceite de Naranja frente a cementos Endodónticos (estudio in vitro) en la Universidad Católica de Cuenca 2017es_ES
dc.typeinfo:eu-repo/semantics/bachelorThesises_ES
dc.typeinfo:eu-repo/semantics/publishedVersiones_ES
thesis.degree.levelTítulo Profesionales_ES
Archivos
Bloque original
Mostrando 1 - 1 de 1
Cargando...
Miniatura
Nombre:
Tesis Final (1).pdf
Tamaño:
3.3 MB
Formato:
Adobe Portable Document Format
Descripción: