Análisis de la tasa de fallos del control eléctrico de secadoras de ropa industrial en condiciones de operación variables

Fecha

2020

Título de la revista

ISSN de la revista

Título del volumen

Editor

Universidad Católica de Cuenca.

Resumen

This research is presented to investigate the most likely causes of failure in operating conditions, nominal and variable, to which the control cards of the speed queen industrial dryers, std32dg, are exposed. It proposes to improve and extend the service life of the fresh laundry located in Cuenca City. Economic factors of time and operation make the study of mainboard failure be mandatory. Presumably, the heat excessive humidity and the flow, has as effect that the boards get damaged easily, and it causes, waste of money and time. When any of the controller boards fails, the downtime of the dryer is typically indefinite. This study will allow to know the most probable causes of failure of the control boards of the drying machines through data taken by the sensors and to carry out an analysis by means of graphs to determine the possible failures. Using the dht 11 sensor, the humidity and temperature data of the control board will be gotten, with the current sensor sct-013-30a, the current data will be obtained on the control boards and with the micro sd module we backed up the information. Data was gotten at the input of the control board both on the card without failure vs the card with failure, the data obtained are temperature, humidity and flow, in the same way data was gotten at the output of the control card, it was obtained data of vacuum current and with different types of clothes (light, jean, towels), weight (5, 10, 20lbs). The comparisons of temperature, humidity, flow were made and it was determined that there was no anomaly in the control card, because the peaks that were presented were at the start of the machine and was within the established parameters. It is recommended to the owner of the laundry the placement of a capacitor bank due to the penalty because of the existing power factor.

Descripción

ESTE DOCUMENTO PRESENTA UNA PROPUESTA DE INVESTIGACIÓN DE LAS CAUSAS MÁS PROBABLES DE FALLA EN CONDICIONES DE OPERACIÓN, NOMINALES Y VARIABLES, A LAS QUE ESTÁN EXPUESTAS LAS TARJETAS DE CONTROL DE LAS SECADORAS INDUSTRIALES SPEED QUEEN, STD32DG. CON ESTA PROPUESTA SE ESPERA MEJORAR Y ALARGAR LA VIDA ÚTIL DE LAS SECADORAS DE LA LAVANDERÍA FRESH UBICADA EN LA CIUDAD DE CUENCA. FACTORES ECONÓMICOS DE TIEMPO Y DE OPERACIÓN HACEN QUE EL ESTUDIO DE LAS TASAS DE FALLAS DE LAS TARJETAS SEA OBLIGATORIO. PRESUMIBLEMENTE, EL CALOR, LA HUMEDAD EXCESIVA Y LA CORRIENTE, PROVOCAN QUE LAS TARJETAS SE ESTROPEEN CON FACILIDAD CREANDO AL PROPIETARIO DE LA LAVANDERÍA ANGUSTIA, PÉRDIDA DE DINERO Y TIEMPO. CUANDO ALGUNA DE LAS TARJETAS CONTROLADORAS FALLA, EL TIEMPO DE PARO DE LA MÁQUINA SECADORA ES TÍPICAMENTE INDEFINIDO. ESTÉ ESTUDIO PERMITIRÁ CONOCER LAS CAUSAS MÁS PROBABLES DE FALLA DE LAS TARJETAS DE CONTROL DE LAS MÁQUINAS SECADORAS A TRAVÉS DE DATOS TOMADOS POR LOS SENSORES Y REALIZAR UN ANÁLISIS MEDIANTE GRÁFICAS PARA DETERMINAR LOS POSIBLES FALLOS. MEDIANTE EL SENSOR DHT 11 SE OBTENDRÁ LOS DATOS DE HUMEDAD Y TEMPERATURA DE LA TARJETA DE CONTROL, CON EL SENSOR DE CORRIENTE SCT-013-30A SE OBTENDRÁ LOS DATOS DE CORRIENTE EN LAS TARJETAS DE CONTROL Y CON EL MÓDULO MICRO SD SE PROCEDIÓ A GUARDAR LOS DATOS OBTENIDOS DURANTE UN TIEMPO. SE TOMÓ DATOS EN LA ENTRADA DE LAS TARJETAS DE CONTROL TANTO EN LA TARJETA SIN FALLA VS LA TARJETA CON FALLA, LOS DATOS OBTENIDOS SON TEMPERATURA, HUMEDAD Y CORRIENTE, DE IGUAL FORMA SE TOMÓ DATOS A LA SALIDA DE LA TARJETA DE CONTROL, SE OBTUVO DATOS DE CORRIENTE AL VACÍO Y CON DIFERENTES TIPOS DE ROPA (LIVIANA, JEAN, TOALLAS), PESO (5, 10,20LIBRAS). SE REALIZARON LAS COMPARACIONES RESPECTIVAS DE TEMPERATURA, HUMEDAD, CORRIENTE Y SE DETERMINÓ QUE NO EXISTÍA NINGUNA ANOMALÍA EN LA TARJETA DE CONTROL, DEBIDO A QUE LOS PICOS QUE SE PRESENTABAN ERAN EN LOS ARRANQUES DE LA MÁQUINA Y ESTABA DENTRO DE LOS PARÁMETROS ESTABLECIDOS. LO QUE SE RECOMIENDA AL DUEÑO DE LA LAVANDERÍA ES LA COLOCACIÓN DE UN BANCO DE CONDENSADORES DEBIDO A LA PENALIZACIÓN POR EL FACTOR DE POTENCIA EXISTENTE.

Palabras clave

TARJETAS DE CONTROL, ANÁLISIS DE DATOS, MEDIDOR DE DATOS

Citación

Ulloa Galindo, C.S. (2020) Análisis de la tasa de fallos del control eléctrico de secadoras de ropa industrial en condiciones de operación variables. Universidad Católica de Cuenca.
logo ucacue
Universidad Católica de Cuenca

Teléfonos:

593 (07) 2-830-7512-830-8772-824-365

Email:

info@ucacue.edu.ecCentro de documentación
logo rraae
logo la referencia