Caracterización del alumbrado público de una sección del alimentador 0423de la Empresa Eléctrica Regional Centro Sur y evaluación de la eficiencia enegética con respecto de luminarias con tecnoligía Led. Caso de estudio: Sector 7 comprendido entre las calles Miraflores y Pasacalle del Cantón Cuenca - Ecuador.

dc.contributor.advisorCabrera Mejía, Frankiln Michael
dc.contributor.authorQuito Sangurima, Santiago Javier
dc.contributor.cedula106522410es_ES
dc.coverageCuenca – Ecuadores_ES
dc.date.accessioned2020-08-13T18:18:59Z
dc.date.available2020-08-13T18:18:59Z
dc.date.issued2015
dc.descriptionEl presente trabajo de tesis consiste en realizar un estudio comparativo sobre la eficiencia energética en alumbrado público, entre la tecnología de lámparas con vapor de sodio y la tecnología de lámparas LED. Para el desarrollo de los comparativos se tomaran datos reales en campo de las lámparas actualmente instaladas en el sector 7 comprendida entre las calles Miraflores y de Pasacalle lugar que se está interviniendo como es el caso de la tecnología de vapor de sodio y para la tecnología LED se instalara en zonas estratégicas una lámpara de esas características para así obtener los datos de campo, los mismos que serán comparados con los datos que se tome en el laboratorio sobre las dos tecnologías, esto nos permitirá identificar la eficiencia energética de cada una de ellas y la factibilidad que ofrece cada tecnología al ser implementada.\n\nLas tomas de datos sobre iluminación de los dos tipos de tecnologías que se está investigando se harán determinando los estado más críticos en el sector, los cuales estarán relacionado a lo atmosférico, topográfico, transitorio tanto peatonal como vehicular.\n\nSe realiza la implementación de un laboratorio de iluminación, dentro de la Facultad de Ingeniería Eléctrica, el mismo que estará adecuado para tomas de datos de distintos tipos de luminarias que permita al estudiante interactuar de una forma práctica y didáctica en los comparativos con datos de laboratorio y campo.\n\nEn el presente laboratorio se realizara la toma de datos de cada una de las tecnologías que se está investigando, debido a que este laboratorio estará equipado con instrumentos de buena calidad, lo nos permitirá tomar los datos de las dos tecnologías de una forma precisa y confiable que a su vez nos garantice nuestra investigación para los comparativos que se realice con los datos de campo obtenidos en el desarrollo de la investigación.es_ES
dc.description.resumenThis present thesis consists of making a comparative study about efficient energy lighting public spaces, Such as vapor lamps containing sodium and LED lamps. For the development of comparisons of such activities date was collected on real time in sector 7 between Miraflores street and Pasacalle place. Which in such places LED and sodium lights will be place to make a real time data collecting of its efficiently . According to these studies placed for the data collecting will show us the efficiency of such cost efficient technologies. This technology’s will be placed in the sectors that are most critical according to use of energy. The studies will be mapped and formatted to show its use and efficiency. This activity will be realized in the lab of illumination in the faculty of electrical engineering which will be adequate for taking data of such project and to be able to study such new technology . Using such lab will guarantee the collection of the data and administrating such results in a controlled and trustworthy environment and also the comparison of the different technologies.\n\nData sockets lighting the two types of technologies under investigation will be determining the most critical state in the sector, which will be related to atmospheric, topographic, both pedestrian and vehicular transient.\n\nImplementing a lighting laboratory within the Faculty of Electrical Engineering, it is done the same as will be suitable for data collections of different types of lights that allows the student to interact in a practical and educational way in comparative laboratory data and field.\n\nIn this laboratory data collection of each of the technologies being investigated, because this laboratory will be equipped with good quality instruments will be held, will allow it we take the data from the two technologies in a way accurate and reliable which in turn will ensure for our research to be performed with comparative field data obtained in the research development.es_ES
dc.formatapplication/pdfes_ES
dc.format.extent204p.es_ES
dc.identifier.other7BT2015-TEle26es_ES
dc.identifier.urihttps://dspace.ucacue.edu.ec/handle/ucacue/6242
dc.language.isospaes_ES
dc.rightsAtribución 4.0 Internacional
dc.rightsinfo:eu-repo/semantics/openAccesses_ES
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/deed.es
dc.sourceUniversidad Católica de Cuencaes_ES
dc.sourceRepositorio Institucional - UCACUEes_ES
dc.subjectEficiencia Energeticaes_ES
dc.subjectLedes_ES
dc.subjectSonidoes_ES
dc.titleCaracterización del alumbrado público de una sección del alimentador 0423de la Empresa Eléctrica Regional Centro Sur y evaluación de la eficiencia enegética con respecto de luminarias con tecnoligía Led. Caso de estudio: Sector 7 comprendido entre las calles Miraflores y Pasacalle del Cantón Cuenca - Ecuador.es_ES
dc.typeinfo:eu-repo/semantics/bachelorThesises_ES
dc.typeinfo:eu-repo/semantics/publishedVersiones_ES
thesis.degree.levelTítulo Profesionales_ES