Efectividad del uso de páncreas artificial en comparación con la bomba de infusión de insulina tradicional para el control glucémico de pacientes pediátricos con Diabetes tipo 1: revisión sistemática

dc.contributor.advisorSucuzhañay Ochoa, María Eugenia
dc.contributor.authorEcheverría Rodríguez, Francis Ramiro
dc.contributor.authorSucuzhañay Ochoa, María Eugenia
dc.contributor.cedula1004253546
dc.contributor.cedula0302141304
dc.coverageAzogues - Ecuador
dc.date.accessioned2026-03-12T12:29:22Z
dc.date.available2026-03-12T12:29:22Z
dc.date.issued2026
dc.descriptionEfectividad del uso de páncreas artificial en comparación con la bomba de infusión de insulina tradicional para el control glucémico de pacientes pediátricos con Diabetes tipo 1: revisión sistemática. Objetivos: Evaluar la efectividad del páncreas artificial frente a las bombas de infusión tradicional en el control glucémico de pacientes pediátricos con Diabetes tipo 1, mediante el análisis del tiempo en rango. Metodología: Investigación sistemática de ensayos clínicos aleatorizados (ECA), realizada conforme a las directrices de las guías PRISMA 2020. Se incluyeron ECA publicados en español o inglés desde 2015 hasta 2025 con acceso libre y texto completo, que comparan el páncreas artificial (PA) frente a bombas de infusión en menores de 20 años. Se excluyeron publicaciones antes de 2015, de pago, con texto incompleto y en idiomas distintos de los mencionados anteriormente. Fuentes: repositorio virtual y físico de la Universidad Católica de Cuenca, bases de datos: PubMed, Scopus, Science Direct y Springer Link. Riesgo de sesgo: Evaluado mediante la herramienta Cochrane Review Manager 5.4.1. Resultados: Se incluyeron 16 artículos correspondientes a ECA que analizaron la repercusión de la terapia en 1,532 participantes. Los hallazgos evidenciaron que el PA incrementó el tiempo en rango (TIR) en un promedio de 2,5-3 horas diarias, redujo los niveles de HbA1c y los episodios hipoglucémicos nocturnos sin incrementar eventos de cetoacidosis. Conclusiones: El PA es más efectivo y seguro que la bomba tradicional para el control glucémico pediátrico. Los médicos deben priorizar su uso para optimizar el TIR y aliviar el impacto en los cuidadores.
dc.description.abstractEffectiveness of an artificial pancreas compared with traditional insulin infusion pumps for Glycemic control in pediatric patients with type 1 Diabetes: A systematic review. Objectives: To evaluate the effectiveness of an artificial pancreas compared with traditional insulin infusion pumps for glycemic control in pediatric patients with Type 1 diabetes, through time-in-range analysis. Methodology: A systematic review of randomized clinical trials (RCTs) conducted in accordance with PRISMA 2020 guidelines. RCTs published in Spanish or English between 2015 and 2025 with open access and full text, comparing artificial pancreas (AP) systems with insulin infusion pumps in individuals under 20 years of age, were included. Publications before 2015, paid-access publications, incomplete texts, and publications in languages other than those mentioned above were excluded. Sources: The virtual and physical repository of the Catholic University of Cuenca and the databases PubMed, Scopus, ScienceDirect, and SpringerLink. Risk of Bias: The evaluation was conducted using the Cochrane Review Manager 5.4.1 tool. Results: 16 articles corresponding to the RCTs that analyzed the impact of the therapy on 1,532 participants were included. The findings revealed that the AP increased time in range (TIR) by an average of 2.5–3 hours per day, reduced HbA1c levels and nocturnal hypoglycemia episodes without increasing ketoacidosis events. Conclusions: The artificial pancreas is more effective and safer than traditional insulin pumps for glycemic control in pediatric patients. Physicians should prioritize its use to optimize TIR and reduce caregiver burden. Keywords: insulin pumps, type 1 diabetes, artificial pancreas, pediatric
dc.description.uriTrabajo de investigación
dc.formatapplication/pdf
dc.format.extentx, 33 páginas
dc.identifier.citationEcheverría Rodríguez F.R. Sucuzhañay Ochoa, M.E. (2026) Efectividad del uso de páncreas artificial en comparación con la bomba de infusión de insulina tradicional para el control glucémico de pacientes pediátricos con Diabetes tipo 1: revisión sistemática. Universidad Católica de Cuenca
dc.identifier.other10BT2026-TMed-3
dc.identifier.urihttps://dspace.ucacue.edu.ec/handle/ucacue/21552
dc.language.isospa
dc.publisherUniversidad Católica de Cuenca.es_ES
dc.relation.urihttp://creativecommons.org/licenses/by/4.0/deed.es
dc.rightsinfo:eu-repo/semantics/openAccesses_ES
dc.rightsAtribución 4.0 Internacionales_ES
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/deed.eses_ES
dc.sourceUniversidad Católica de Cuencaes_ES
dc.sourceRepositorio Institucional - UCACUEes_ES
dc.subjectBOMBAS DE INSULINA, DIABETES TIPO 1, PÁNCREAS ARTIFICIAL, PEDIATRÍA
dc.titleEfectividad del uso de páncreas artificial en comparación con la bomba de infusión de insulina tradicional para el control glucémico de pacientes pediátricos con Diabetes tipo 1: revisión sistemática
dc.typeinfo:eu-repo/semantics/article
thesis.degree.disciplineSalud y servicios sociales
thesis.degree.grantorUniversidad Católica de Cuenca, Campus Azogues. Medicina
thesis.degree.levelTítulo Profesional
thesis.degree.namePregrado
thesis.degree.programPresencial

Archivos

Bloque original

Mostrando 1 - 1 de 1
Cargando...
Miniatura
Nombre:
FRANCIS RAMIRO ECHEVERRÍA RODRÍGUEZ - MARÍA EUGENIA SUCUZHAÑ.pdf
Tamaño:
2.41 MB
Formato:
Adobe Portable Document Format
logo ucacue
Universidad Católica de Cuenca

Teléfonos:

593 (07) 2-830-7512-830-8772-824-365

Email:

info@ucacue.edu.ecCentro de documentación
logo rraae
logo la referencia