Valoración de un esfigmomanómetro aneroide de presión modificada para la insuflación del balón de neumatoponamiento del tubo endotraqueal en perros

dc.contributor.advisorCastillo Hidalgo, Edy Paúl
dc.contributor.authorMuela Carreño , Kerly de los Angeles
dc.contributor.cedula0302478581
dc.coverageCuenca-Ecuador
dc.date.accessioned2024-05-29T21:48:45Z
dc.date.available2024-05-29T21:48:45Z
dc.date.issued2021
dc.descriptionEl presente trabajo titulado “Valoración de un esfigmomanómetro aneroide de presión modificado para la insuflación del balón de neumotaponamiento del tubo endotraqueal en perros” se desarrolló con el fin de realizar un estudio que permita conocer los valores exactos para la inyección de aire en el balón del neumotaponamiento, estudio que fue realizado en las instalaciones de la clínica veterinaria “Le Peluts”. Se experimentó con el tubo endotraqueal con manguito de baja presión y de alto volumen gracias a la ayuda de una llave de tres vías conectando a un extremo de la llave del esfigmomanómetro, el otro extremo al balón piloto y la última llave se conecta con una jeringa. El primer método que se realizo es la técnica de la digito-palpación donde no se midió la cantidad de aire que se envía al balón de neumotaponamiento, la segunda técnica fue con el esfigmomanómetro en la cual si se pudo medir la presión de aire que se mandaba al balón de neumotaponamiento es ahí donde se verifica cuál de las dos técnicas es la más factible para evitar patologías que se produzca durante y después de la intubación con el traqueotubo. No se observó cambios físicos en las muestras que se tomaron utilizando el esfigmomanómetro. El segundo método, que es la técnica de la digito-presión se observaron cambios morfológicos es decir que hubo irritación, ulceras superficiales y profundas en el paciente Palabras claves: endotraqueal, esfigmomanómetro, insuflación, aneroide, neumotaponamiento.
dc.description.abstractThis paper entitled "Evaluation of a modified aneroid pressure sphygmomanometer for the insufflation of the endotracheal tube cuff balloon in dogs" was developed to conduct a study to determine the exact values for the injection of air into the endotracheal cuff balloon. This study was carried out at the facilities of the "Le Peluts" veterinary clinic. The endotracheal tube with low pressure and high volume cuff was developed with the help of a three-way key connecting one end of the key to the sphygmomanometer, the other end to the pilot balloon and the last key is connected to a syringe. The first method that was performed is the technique of digital-palpation where the amount of air that is sent to the endotracheal cuff balloon was not measured, the second technique was with the sphygmomanometer in which it was possible to measure the air pressure that was sent to the endotracheal cuff balloon and it is there where it is verified which of the two techniques is the most feasible to avoid pathologies that occur during and after intubation with the endotracheal tube. No physical changes were observed in the samples taken using the sphygmomanometer. In the second method, which is the digital-pressure technique, morphological changes were observed, that is to say, that there was irritation, superficial and deep ulcers in the patient. KEYWORDS: ENDOTRACHEAL, SPHYGMOMANOMETER, INSUFFLATION, ANEROID, ENDOTRACHEAL INTUBATION PROCEDURE
dc.description.uriTesis
dc.format.extent75
dc.identifier.citationApa
dc.identifier.other4BT2021-VT10
dc.identifier.urihttps://dspace.ucacue.edu.ec/handle/ucacue/17637
dc.language.isospa
dc.publisherUniversidad Católica de Cuenca.es_ES
dc.rightsinfo:eu-repo/semantics/openAccesses_ES
dc.rightsAtribución 4.0 Internacionales_ES
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/deed.eses_ES
dc.sourceUniversidad Católica de Cuencaes_ES
dc.sourceRepositorio Institucional - UCACUEes_ES
dc.subjectendotraqueal
dc.subjectesfigmomanómetro
dc.subjectinsuflación
dc.subjectaneroide
dc.subjectneumotaponamiento
dc.titleValoración de un esfigmomanómetro aneroide de presión modificada para la insuflación del balón de neumatoponamiento del tubo endotraqueal en perros
dc.typeinfo:eu-repo/semantics/bachelorThesis
thesis.degree.disciplineCarrera de veterinaria
thesis.degree.grantorUniversidad Católica de Cuenca. Unidad de Agronomía
thesis.degree.levelTítulo Profesional
thesis.degree.nameMédico Veterinario
thesis.degree.programPresencial

Archivos

Bloque original

Mostrando 1 - 1 de 1
Cargando...
Miniatura
Nombre:
Tesis Modificada K.M..pdf
Tamaño:
1.52 MB
Formato:
Adobe Portable Document Format

Bloque de licencias

Mostrando 1 - 1 de 1
Cargando...
Miniatura
Nombre:
license.txt
Tamaño:
1.27 KB
Formato:
Item-specific license agreed upon to submission
Descripción:
logo ucacue
Universidad Católica de Cuenca

Teléfonos:

593 (07) 2-830-7512-830-8772-824-365

Email:

info@ucacue.edu.ecCentro de documentación
logo rraae
logo la referencia