Caracterización del alumbrado público de una sección del alimentador 0423de la Empresa Eléctrica Regional Centro Sur y evaluación de la eficiencia enegética con respecto de luminarias con tecnoligía Led. Caso de estudio: Sector 9 comprendido entre las calles del Pasacalle, Cumana, Ayancay, Benjamin Franklin, Av. Miraflores, Graham Bell, Pedro Franco Davila, Yaupi, Guillermo Marconi, Marie Curie y la Florestina del Cantón Cuenca - Ecuador.

dc.contributor.advisorCabrera Mejía, Frankiln Michael
dc.contributor.authorZaruma Zaruma, Bolivar Fernando
dc.contributor.cedula301249462es_ES
dc.coverageCuenca – Ecuadores_ES
dc.date.accessioned2020-08-13T18:18:59Z
dc.date.available2020-08-13T18:18:59Z
dc.date.issued2015
dc.descriptionEn este proyecto de Investigación se ha plateado desarrollar varios aspectos importantes, el primero de los cuales consiste en elaborar la caracterización del alumbrado público de un segmento del alimentador 0423 de la Empresa Eléctrica Regional Centro Sur; en segundo lugar pretende evaluar la eficiencia energética en el alumbrado público, comparando entre la tecnología convencional (lámparas con vapor de sodio) y la tecnología de iluminación LED.\nA fin de ejecutar una correcta investigación se ha obtenido información real acerca de las luminarias que se encuentran instaladas en las siguientes calles del cantón Cuenca: Del Pasacalle, Cumaná, Ayancay, Benjamín Franklin, Avenida Miraflores, Graham Bell, Pedro Franco Dávila, Yaupi, Guillermo Marconi, Marie Curie, Morse y la Floresta. Mismas que corresponden específicamente al sector 9, en el cual se trabajó a fin de conseguir datos de campo acerca tanto de la tecnología de vapor de sodio, como también de la tecnología LED, para la cual fueron instaladas luminarias de ese tipo en zonas específicas a fin de obtener los datos requeridos. Es con ambos grupos de datos que se ha planteado realizar una comparación con la información conseguida en laboratorio acerca de ambas tecnologías, todo esto con el objetivo de determinar la eficiencia energética que posee cada una, así como la factibilidad de cada tecnología de poder implementarse.\nLa información obtenida tras estos procesos se desarrolló mediante la delimitación de los estados más críticos existentes en la zona, mismos que se relacionan a lo topográfico, lo atmosférico, y lo transitorio, tanto peatonal como vehicular. Así mismo, en la Facultad de Ingeniería Eléctrica se implementó un laboratorio de luminotécnica, adecuándolo de forma que el estudiante pueda interactuar tanto a nivel práctico como didáctico en la obtención de los diferentes datos de cada una de las tecnologías, tanto a nivel laboratorio como de campo y la consiguiente realización de las comparaciones pertinentes. Ya que dicho laboratorio posee equipos de gran calidad, se ha logrado obtener una información confiable y muy exacta, lo que respalda y asegura la presente investigación desarrollada que se exhibe a continuaciónes_ES
dc.description.resumenIn this research project it was to develop several important aspects silver, the first of which is to develop Characterization Street lighting feeder segment of the 0423 South Central Regional Electricity Company; secondly it aims to evaluate energy efficiency in street lighting, comparing between conventional technology (sodium vapor lamps) and LED lighting technology.\n\nIn order to run a proper investigation has been obtained real information about the lights that are installed in the following streets of Canton Cuenca: Del Pasacalle, Cumana, Ayancay, Benjamin Franklin, Avenida Miraflores, Graham Bell, Pedro Franco Dávila, Yaupi, Guillermo Marconi, Marie Curie, Morse and Floresta. Same that are specific to Sector 9, in which we worked to get field data about both technology sodium vapor, as well as the LED technology, which were installed luminaries such in specific areas In order to obtain the required data. It is with both sets of data that has been raised a comparison with the information obtained in the laboratory on both technologies, all with the objective of determining the energy efficiency that has each, as well as the feasibility of each technology to be implemented.\n\nThe information obtained from these processes are developed by the division of existing critical states in the area, which are related to topographic, so atmospheric, and the transient, both pedestrian and vehicular. Likewise, in the Faculty of Electrical Engineering laboratory lighting, adapting it so that students can interact both practical and educational level in obtaining the different data of each of the technologies at both laboratory and it was implemented field and the subsequent implementation of relevant comparisons. Since this laboratory has high-quality equipment, it has achieved a very reliable and accurate information, which supports and ensures the present research conducted on display below.es_ES
dc.formatapplication/pdfes_ES
dc.format.extent202p.es_ES
dc.identifier.other7BT2015-TEle25
dc.identifier.urihttps://dspace.ucacue.edu.ec/handle/ucacue/6244
dc.language.isospaes_ES
dc.rightsAtribución 4.0 Internacional
dc.rightsinfo:eu-repo/semantics/openAccesses_ES
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/deed.es
dc.sourceUniversidad Católica de Cuencaes_ES
dc.sourceRepositorio Institucional - UCACUEes_ES
dc.subjectEficiencia Energeticaes_ES
dc.subjectLedes_ES
dc.subjectSonidoes_ES
dc.titleCaracterización del alumbrado público de una sección del alimentador 0423de la Empresa Eléctrica Regional Centro Sur y evaluación de la eficiencia enegética con respecto de luminarias con tecnoligía Led. Caso de estudio: Sector 9 comprendido entre las calles del Pasacalle, Cumana, Ayancay, Benjamin Franklin, Av. Miraflores, Graham Bell, Pedro Franco Davila, Yaupi, Guillermo Marconi, Marie Curie y la Florestina del Cantón Cuenca - Ecuador.es_ES
dc.typeinfo:eu-repo/semantics/bachelorThesises_ES
dc.typeinfo:eu-repo/semantics/publishedVersiones_ES
thesis.degree.levelTítulo Profesionales_ES
Archivos