Proyectos de titulación. Electricidad
URI permanente para esta colecciónhttps://dspace.ucacue.edu.ec/handle/ucacue/23123
Examinar
Envíos recientes
Item type: Ítem , Access status: Acceso Abierto , Análisis de calidad de energía en el banco de capacitores en el sistema eléctrico del Terminal Cuenca de Petroecuador(Universidad Católica de Cuenca, 2026) Dominguez Banegas, Christian JesusThis research aimed to determine the current reactive power requirements of the electrical system at EP Petroecuador’s Cuenca Clean Products Terminal by analyzing power quality under the actual operating conditions of the existing load. The study employed a quantitative, descriptive, and analytical approach. A Fluke 435 Series II Power Quality Analyzer was used as the primary measurement instrument to record electrical parameters, including voltage, current, active power, reactive power, apparent power, power factor, and total voltage harmonic distortion (THDv). Additionally, available historical electricity billing data were examined to assess power factor behavior and determine the facility’s reactive power compensation requirements. Finally, compliance of total voltage harmonic distortion levels with the limits established by IEEE Standard 519-2022 was verified.Item type: Ítem , Access status: Acceso Abierto , Impacto técnico del autoconsumo fotovoltaico residencial en el alivio de carga de redes de distribución de baja tensión(Universidad Católica de Cuenca, 2026) Aguilar Chacón, Francisco Javier; Cócheres Arcentales, Richard LeonardoResidential photovoltaic self-consumption is a technical alternative for reducing the net demand observed by distribution transformers during hours of solar generation. This study analyzes the impact of integrating residential photovoltaic systems into the low-voltage grid associated with transformer 5504 in the Puertas del Sol sector of the city of Cuenca. The methodology includes characterizing the grid, electrical modeling in DIgSILENT PowerFactory, estimating photovoltaic power per user, constructing an hourly generation curve using PVsyst, and simulating photovoltaic penetration scenarios of 20%, 60%, 80%, and 100%. The results show that the greatest load relief on the transformer occurs at 3:00 p.m. At this time, the load factor decreases from 54.20% in the baseline scenario to 18.47% in the 100% photovoltaic penetration scenario, representing a reduction of 65.92%. Likewise, active power losses decrease from 0.25 kW to 0.10 kW, equivalent to a 60.00% reduction. Voltage profiles improve mainly at the midpoint and end of the grid, with no overvoltage conditions occurring. In contrast, at 8:00 p.m., the load capacity remains at 122.98% due to the absence of photovoltaic generation. The results show that photovoltaic self-consumption helps relieve the transformer load and reduce losses during hours with solar availability, but it does not resolve the critical nighttime condition when energy storage is not available.Item type: Ítem , Access status: Acceso Abierto , Sistema de supervisión automatizada para el reconocimiento y conteo taxonómico de vehículos mediante algoritmos de visión artificial(Universidad Católica de Cuenca, 2026) Agreda Ordoñez, Jose AndresThe growth of the vehicle fleet and the need for reliable vehicle monitoring systems contrast with the high costs of commercial solutions. This motivated the present study to develop and implement a low-cost automated system for vehicle recognition and classification and counting by vehicle type using computer vision algorithms. To this end, an IoT architecture was designed based on an ESP32-CAM node with a W5500 module for transmitting video over Ethernet to a local server, where a YOLO (You Only Look Once) model incorporating tracking techniques and a virtual line was used to classify and count cars, buses, trucks, and motorcycles. The system was evaluated over four weeks at three locations on the main campus of the Catholic University of Cuenca, two of which were powered by standalone photovoltaic systems. Validation, based on a comparison of 11,998 automatically counted vehicles with 13,966 vehicles recorded through manual counting, showed an overall agreement of 85.91% and F1-scores ranging from 75.96% to 86.08%. The best performance was achieved for cars, with an error rate of 12.48%, while motorcycles showed the highest error rate, at 22.38%. Meanwhile, the camera's lateral viewing angle proved to be a determining factor in the error observed in the Basílica sector. The total cost was USD 412.62, equivalent to USD 137.54 per monitoring point, significantly lower than the cost of commercial radar-based systems. It is concluded that integrating low-cost embedded nodes, centralized processing, and solar power constitutes a technically and economically viable alternative for urban traffic monitoring.Item type: Ítem , Access status: Acceso Abierto , Proyecto de Titulación embargado con fines de publicación de impacto(Universidad Católica de Cuenca, 2026) Tapia Alvarez, Roberto CarlosItem type: Ítem , Access status: Acceso Abierto , Análisis de las redes de telecomunicaciones basado en algoritmos de lógica difusa para los sistemas de medición inteligente AMI(Universidad Católica de Cuenca, 2026) Nivelo Galarza, Carlos SebastiánThis research analyzes the performance of telecommunications networks used in advanced metering infrastructure (AMI) systems by applying fuzzy logic and the theory of forgotten effects, using feeder 1522 in the canton of Gualaceo as a case study. The study aims to mitigate non-technical losses, improve system reliability, and enhance data transmission in complex electrical environments. The methodology included a systematic literature review and technical input from specialists at the Empresa Eléctrica Regional Centro Sur, enabling the identification and quantification of key variables through the use of normalized fuzzy matrices. The study identified twelve causal factors and twelve effects related to infrastructure, security, data availability, and service quality. Using a MATLAB model with max-min fuzzy composition, the study calculated the forgotten effects and categorized the variables according to their level of impact. The results show that the negative impact of cryptographic key management, firmware updates, bandwidth, cyberattacks, and defective hardware in meters or concentrators represents the factors that most affect the performance of the AMI system. It was also found that previously overlooked effects concealed indirect relationships that the initial evaluation had not considered, particularly the relationship between security and authentication. These findings demonstrate that combining fuzzy logic with the matrix analysis of forgotten effects provides a valuable tool for technical decision-making and can improve system reliability under real-world conditions.




